Cargo · Liquefied gases

LPG carriers: pressurised, semi-refrigerated and fully refrigerated

Check IGC requirements for propane, butane or the actual LPG mixture; pressure vessels and low-pressure refrigerated containment need different assessments. Propane and butane are listed as 2G/2PG; 2PG requires the specified vessel length, Type C tanks, pressure and design-temperature conditions.

Propane constituent boiling point

−42°C

Disclosed

[S1]

n-Butane constituent boiling point

−0.5°C

Disclosed

[S2]

Propane and butane ship types

2G/2PG

Disclosed

[S3]

2PG tank condition

Type C independent tanks

Disclosed

[S3]

Constituent gas density

Propane and n-butane are heavier than air

Disclosed

[S1][S2]

Properties and data scope

PropertyValue or scopeUnitTag and source
Data scopePropane and n-butane constituents, not the whole LPG cargo—Disclosed[S1][S2]
Propane CAS number74-98-6—Disclosed[S1]
Propane boiling point−42°CDisclosed[S1]
Propane vapour pressure (20°C)840kPaDisclosed[S1]
Propane explosive limits in air2.1–9.5% volDisclosed[S1]
n-Butane CAS number106-97-8—Disclosed[S2]
n-Butane boiling point−0.5°CDisclosed[S2]
n-Butane vapour pressure (21.1°C)213.7kPaDisclosed[S2]
n-Butane explosive limits in air1.8–8.4% volDisclosed[S2]

IGC ship types and 2PG conditions

Propane and butane are listed as 2G/2PG, not examples of 3G. The 2PG conditions include length no greater than 150 m, Type C independent tanks, MARVS of at least 0.7 MPa gauge and cargo-system design temperature no lower than −55°C.[S3]

Verify carriage against the current IBC/IGC text, the actual product entry in Chapter 19 and the vessel's Certificate of Fitness. The 2PG conditions do not mean that all LPG vessels require Type C tanks.[S3][S5]

Pressure, refrigeration and operational preparation

Pressurised, semi-refrigerated and fully refrigerated labels alone do not establish permitted containment or operating temperature and pressure. Check the actual cargo, approved vessel containment design and operations manual against the latest flag/class requirements; this page does not assign a one-to-one mapping from commercial vessel labels to tank types or universal temperature-pressure values.[S3][S4]

Plan cargo changes and maintenance under the cargo operations manual, including cooling, warming, inerting and transfer operations. Confirm communications and emergency shutdown before transfer; an ordinary liquid-cargo water-washing routine does not replace gas-carrier procedures.[S5]

The MSC.370(93) Chapter 19 Propane and Butane (all isomers) rows both list 2G/2PG in column c, “–” for Type C requirements in d and environmental control in e, F (flammable vapour detection) in f, R (indirect, closed or restricted gauging) in g, and no listed special provisions in i. General requirements, 2PG conditions and the vessel’s Certificate of Fitness still apply.[S6]

Leakage, low-space accumulation and constituent limits

ICSC states that propane and n-butane are heavier than air, can collect in low spaces and ignite at a distant source, and can cause oxygen deficiency through air displacement. Liquid contact can cause frostbite; control ignition sources, provide ventilation and check oxygen.[S1][S2]

The two cards give separate propane and n-butane boiling points and vapour pressures, with different pressure-test temperatures. Do not average them into LPG mixture properties or use n-butane values for isobutane.[S1][S2]

Questions

Are propane and butane 3G cargoes?

Propane and butane are listed as 2G/2PG. Check the current Chapter 19 entry and vessel certificate.

Do all LPG vessels require Type C tanks?

No. Type C is a 2PG condition; check other arrangements against the product and vessel design.

Can the n-butane boiling point represent an LPG mixture?

No. −0.5°C is n-butane data from ICSC 0232; use actual constituent information for a mixture.

Why focus on low spaces after a leak?

Propane and n-butane are heavier than air and can collect in low spaces, creating flammability and oxygen-deficiency hazards.