Cargo · Liquefied gases

LNG carriers: IGC ship type, tanks and boil-off gas

Check LNG ship type, containment and temperature-pressure control under IGC; large carriers commonly use Type B independent tanks or membrane systems. Handle boil-off gas under the vessel's design, including fuel use where applicable; methane properties describe a constituent rather than every LNG cargo.

Methane constituent boiling point

−161°C (ICSC 0291)

Disclosed

[S1]

Methane explosive limits in air

5–15% by volume

Disclosed

[S1]

Ship type

LNG: 2G; verify the product entry

Disclosed

[S2]

Common containment on large carriers

Type B independent tanks or membrane tanks

Disclosed

[S2]

Boil-off gas handling

May be used as fuel under the system and rules

Disclosed

[S3]

Properties and data scope

PropertyValue or scopeUnitTag and source
Property scopeMethane constituent, not the whole LNG cargo—Disclosed[S1]
Methane CAS number74-82-8—Disclosed[S1]
Methane boiling point−161°CDisclosed[S1]
Methane melting point−183°CDisclosed[S1]
Methane relative gas density (air = 1)0.6—Disclosed[S1]
Methane explosive limits in air5–15% volDisclosed[S1]
Methane autoignition temperature537°CDisclosed[S1]

IGC ship type and containment

LNG is listed as 2G, with Type B independent tanks and membrane tanks as typical large-carrier arrangements. Smaller LNG vessels may use Type C pressure vessels. These examples are not an exclusive tank-type list.[S2]

The MSC.370(93) Chapter 19 Methane (LNG) row lists 2G in column c, “–” for Type C requirements in d and environmental control in e, F (flammable vapour detection) in f, C (indirect or closed gauging) in g, and no listed special provisions in i. These entries do not waive general requirements; check applicable amendments and the vessel’s Certificate of Fitness.[S6]

Boil-off gas, temperature-pressure control and atmosphere changes

There are four temperature-pressure control routes: reliquefaction, thermal oxidation, pressure accumulation and liquid cargo cooling. Fuel use and combustion disposal are different thermal-oxidation routes; do not use venting as normal pressure control.[S3][S4]

Methane vapour used as fuel must comply with Chapter 16 piping, ventilation, gas detection and automatic shutoff arrangements. Monitor tank pressure, temperature and boil-off gas destination under the vessel's system.[S3][S4]

Atmosphere changes for maintenance require the inert-gas transition procedure rather than directly replacing cargo vapour with air through a flammable range. Completing the atmosphere change does not replace entry permission.[S4]

Cryogenic contact, leakage and oxygen deficiency

ICSC 0291 identifies frostbite from rapid liquid-methane evaporation and suffocation from oxygen displacement in confined areas. Cryogenic LNG can cause material embrittlement, and cold LNG vapour can spread along deck before warming.[S1][S5]

ICSC methane data describe that constituent only. Check whole-cargo LNG boiling point, density, carriage temperature and boil-off arrangements against actual cargo information and vessel systems; this page does not assign universal properties or a daily boil-off rate.[S1][S5]

Questions

Must LNG use membrane tanks?

No. Type B independent tanks are another option, with possible Type C tanks on smaller vessels. Check product requirements and vessel design.

Is −161°C a universal boiling point for all LNG cargoes?

No. It is methane constituent data from ICSC 0291; check actual cargo information for mixed LNG cargo.

Must all boil-off gas go to the engine?

No. Other pressure-control routes include reliquefaction, pressure accumulation and liquid cargo cooling; follow the vessel's system.

Can gas testing be omitted because methane is not a typical toxic gas?

No. Flammability and oxygen displacement remain hazards; liquid contact can also cause frostbite.

Sources