Cargo · Liquefied gases
LNG carriers: IGC ship type, tanks and boil-off gas
Check LNG ship type, containment and temperature-pressure control under IGC; large carriers commonly use Type B independent tanks or membrane systems. Handle boil-off gas under the vessel's design, including fuel use where applicable; methane properties describe a constituent rather than every LNG cargo.
Properties and data scope
| Property | Value or scope | Unit | Tag and source |
|---|---|---|---|
| Property scope | Methane constituent, not the whole LNG cargo | — | Disclosed[S1] |
| Methane CAS number | 74-82-8 | — | Disclosed[S1] |
| Methane boiling point | −161 | °C | Disclosed[S1] |
| Methane melting point | −183 | °C | Disclosed[S1] |
| Methane relative gas density (air = 1) | 0.6 | — | Disclosed[S1] |
| Methane explosive limits in air | 5–15 | % vol | Disclosed[S1] |
| Methane autoignition temperature | 537 | °C | Disclosed[S1] |
IGC ship type and containment
LNG is listed as 2G, with Type B independent tanks and membrane tanks as typical large-carrier arrangements. Smaller LNG vessels may use Type C pressure vessels. These examples are not an exclusive tank-type list.[S2]
The MSC.370(93) Chapter 19 Methane (LNG) row lists 2G in column c, “–” for Type C requirements in d and environmental control in e, F (flammable vapour detection) in f, C (indirect or closed gauging) in g, and no listed special provisions in i. These entries do not waive general requirements; check applicable amendments and the vessel’s Certificate of Fitness.[S6]
Boil-off gas, temperature-pressure control and atmosphere changes
There are four temperature-pressure control routes: reliquefaction, thermal oxidation, pressure accumulation and liquid cargo cooling. Fuel use and combustion disposal are different thermal-oxidation routes; do not use venting as normal pressure control.[S3][S4]
Methane vapour used as fuel must comply with Chapter 16 piping, ventilation, gas detection and automatic shutoff arrangements. Monitor tank pressure, temperature and boil-off gas destination under the vessel's system.[S3][S4]
Atmosphere changes for maintenance require the inert-gas transition procedure rather than directly replacing cargo vapour with air through a flammable range. Completing the atmosphere change does not replace entry permission.[S4]
Cryogenic contact, leakage and oxygen deficiency
ICSC 0291 identifies frostbite from rapid liquid-methane evaporation and suffocation from oxygen displacement in confined areas. Cryogenic LNG can cause material embrittlement, and cold LNG vapour can spread along deck before warming.[S1][S5]
ICSC methane data describe that constituent only. Check whole-cargo LNG boiling point, density, carriage temperature and boil-off arrangements against actual cargo information and vessel systems; this page does not assign universal properties or a daily boil-off rate.[S1][S5]
Questions
Must LNG use membrane tanks?
No. Type B independent tanks are another option, with possible Type C tanks on smaller vessels. Check product requirements and vessel design.
Is −161°C a universal boiling point for all LNG cargoes?
No. It is methane constituent data from ICSC 0291; check actual cargo information for mixed LNG cargo.
Must all boil-off gas go to the engine?
No. Other pressure-control routes include reliquefaction, pressure accumulation and liquid cargo cooling; follow the vessel's system.
Can gas testing be omitted because methane is not a typical toxic gas?
No. Flammability and oxygen displacement remain hazards; liquid contact can also cause frostbite.