In one sentence
Before entry, ventilate and verify normal-air oxygen around 20.9%, flammable gas below 1% LFL, toxic gases below 50% of their exposure limits and carbon dioxide below 0.5% by volume, then complete the permit, external attendance and rescue preparations.
Pre-entry atmosphere criteria
| Test | Criterion | Tag and source |
|---|---|---|
| Oxygen | MSC.581(110) uses normal-air oxygen at 20.9% by volume; interpret readings with instrument accuracy and sampling location. | Disclosed[S1] |
| Flammable gases | Below 1% LFL; this is a percentage of the flammable limit, not a volume percentage of gas. | Disclosed[S1] |
| Toxic gases | Below 50% of the relevant gas’s occupational exposure limit; select tests from previous cargo and the risk assessment. | Disclosed[S1] |
| Carbon dioxide | Below 0.5% by volume, equivalent to 5,000 ppm; oxygen testing alone cannot rule out toxic gases. | Disclosed[S1] |
Before and during entry
- 1
- 2
Sample from outside at several points
Stop ventilation for testing and allow conditions to stabilize; sample different locations and heights from outside using equipment suited to the target gases.[S1]
- 3
- 4
Ventilate and retest during occupation
Maintain ventilation and continuous or frequent monitoring during occupation; recheck after breaks and withdraw immediately if conditions deteriorate.[S1]
Rescue must follow the plan
- An unprepared colleague entering to rescue can encounter the same hazard. The attendant must activate the plan and must not enter alone to attempt rescue.[S1][B1]
- An EEBD is for escape, not respiratory protection for oxygen-deficient entry or rescue. Emergency entry requires trained personnel and appropriate breathing equipment under the rescue plan.[B1]
Guidance version and drills
- According to LR’s official notice, the IMO’s 34th Assembly has revoked A.1050(27). The 2025 MSC.581(110) provides revised entry recommendations. The UK’s 2026 MGN 659 Amendment 3 incorporates these recommendations.[S1][S2][S4]
- SOLAS III/19.3.3, inserted by MSC.350(92), requires Crew with enclosed space entry or rescue responsibilities to participate in an onboard entry and rescue drill at least once every two months. Regulation 19.3.6 covers protection, communications, atmosphere testing, rescue and first aid; UK implementing rules also require intervals not exceeding two months.[S2][S3]
Questions
Does normal oxygen alone establish safe entry?
No. Flammable gases, toxic gases and carbon dioxide also need testing, with permits, isolation, attendance and rescue preparations in place.
Does 1% LFL mean 1% gas by volume?
No. It means one hundredth of that gas’s lower flammable limit concentration.
Can an EEBD be used to enter for rescue?
No. It is an escape device. Emergency entry requires trained personnel and suitable breathing equipment under the rescue plan.
Must crew leave if readings worsen after the permit is signed?
Yes. A signed permit does not guarantee a continuing safe atmosphere; withdraw and reassess when conditions deteriorate.
Sources
- [S1]IMO MSC.581(110): revised enclosed space entry recommendations
- [S2]UK MGN 659 Amendment 3: enclosed space entry
- [B1]Enclosed spaces and rescue
- [B2]Work permits and risk controls
- [S3]IMO MSC.350(92): SOLAS III/19 entry and rescue drills
- [S4]LR Class News 04/2026: revised entry recommendations and revocation of A.1050(27)