Cargo · Polymerising monomers
Styrene monomer bulk shipping notes
Styrene monomer can polymerise with heat release; control temperature, oxygen conditions and validity periods according to the inhibitor certificate and cargo instructions. Prevent local overheating and check vents for polymer blockage.
Properties and data scope
| Property | Value or scope | Unit | Tag and source |
|---|---|---|---|
| CAS number | 100-42-5 | — | Disclosed[S1] |
| Closed-cup flash point | 31 | °C | Disclosed[S1] |
| Boiling point | 145 | °C | Disclosed[S1] |
| Melting point | −30.6 | °C | Disclosed[S1] |
| Relative density (water = 1) | 0.91 | — | Disclosed[S1] |
| Vapour pressure (20°C) | 0.67 | kPa | Disclosed[S1] |
| Explosive limits in air | 0.9–6.8 | % vol | Disclosed[S1] |
IBC entry and inhibitor certificate
The MEPC.318(74) Chapter 17 Styrene monomer entry lists Y in column c, ship type 3 in e and tank type 2G (integral gravity) in f. Column o lists 15.12, 15.13, 15.17, 15.19.6 and 16.6.1–.2, covering toxicity, inhibitors, ventilation, high-level alarms and prevention of local overheating.[S6]
ClassNK Part S 15.13.3 requires the inhibitor certificate to specify name and amount, oxygen dependence, addition date and effective duration, temperature limitations affecting effectiveness and action if the voyage exceeds that duration. Check oxygen conditions and cargo temperature against the actual certificate and cargo instructions. An inhibited label does not replace monitoring; verify applicable rules and the vessel’s Certificate of Fitness.[S7]
Temperature records and cleaning checks
Control cargo temperature under the certificate, watch for rapid temperature rise and local overheating, and retain temperature records.[S2][S3]
ICSC notes that uninhibited styrene vapour can polymerise in vents and flame arresters and block them. Devices must be accessible for inspection, cleaning and replacement; vent-outlet ventilation criteria do not constitute entry permission.[S1][S4]
MAIB investigated the 28 September 2019 Stolt Groenland accident at Ulsan on behalf of the Cayman Islands Government. Section 3.1 concludes that heat transferred through an intermediate tank raised styrene temperature, reduced TBC inhibitor effectiveness and led to runaway polymerisation. The cargo temperature was not monitored during the voyage and temperature alarms were not set.[S8]
Oxygen conditions and incompatible materials
No in Chapter 17 column h does not prohibit inerting. Check inhibitor certificate oxygen requirements rather than copying oil-tanker oxygen limits.[S5]
Heat, light, oxidants, oxygen and peroxides can trigger polymerisation. Styrene reacts violently with strong acids and oxidants and attacks rubber, copper and copper alloys.[S1]
Questions
Must styrene always be inerted?
There is no blanket answer. No in Chapter 17 column h does not prohibit inerting; check certificate oxygen conditions.
Why inspect vents for polymers?
ICSC notes that uninhibited styrene vapour may polymerise in vents and flame arresters and block them.
Can one temperature limit cover all styrene cargoes?
Follow cargo information, the inhibitor certificate and cargo instructions for cargo temperature limits.
What is the flash point of styrene?
ICSC 0073 reports a closed-cup flash point of 31°C and boiling point of 145°C.